Y301-0004/0006/0008 Analog Output Modules

Compare Y301 analog output modules with 4, 6 or 8 channels and voltage or current output options.

  • Modbus-RTU
  • RS485
  • Analog Output
  • 0-10V
  • 4-20mA

Key Features

01

Y301-0004 provides four 14-bit analog outputs for HVAC and OEM controls, with 0-10 V or 4-20 mA options and Modbus RTU/ASCII over isolated RS485.

02

Y301-0006 adds six 14-bit analog outputs to process skids, with 0-10 V or 4-20 mA options and Modbus RTU/ASCII through isolated RS485 or optional RS232.

03

Y301-0008 controls eight analog outputs over Modbus RTU/ASCII for PLC and SCADA systems, with 14-bit conversion and 0-10 V, 4-20 mA, or combo options.

Specifications

Y301-0004

Power Supply
Voltage: DC 12~30V; Typical Power Consumption: 11 mA @ 24V (~0.26 W); Operating Temperature: -40°C ~ +85°C; Humidity: 0% ~ 95% RH, non-condensing
Analog Outputs
Channels: 4; Output Type: 0-10 V, 4-20 mA, or combo option; combo versions support per-channel mode selection; Resolution: 14-bit (16384 steps); Accuracy: +/-0.1% FS; Linearity: +/-0.1% FS; Settling Time: <10 ms; Output Impedance: Voltage mode: <10 ohm; current mode: >10 Mohm; Load Capability: Voltage mode: >2 kohm; current mode: <600 ohm; Output Retention: Optional; restores the last output value after reboot when enabled
Communication
Interfaces: Opto-isolated RS485, optional RS232; Protocol: Modbus RTU / Modbus ASCII / Modbus TCP via gateway; Baud Rate: 600~115200 bps (auto-detect); Address Range: 1~255; Isolation Voltage: 1500 V RMS (RS485)
Mechanical
Dimensions: 100 x 70 x 35 mm

Y301-0006

Power Supply
Voltage: DC 12~30V; Typical Power Consumption: 11 mA @ 24V (~0.26 W); Operating Temperature: -40°C ~ +85°C; Humidity: 0% ~ 95% RH, non-condensing
Analog Outputs
Channels: 6; Output Type: 0-10 V, 4-20 mA, or combo option; combo versions support per-channel mode selection; Resolution: 14-bit (16384 steps); Accuracy: +/-0.1% FS; Linearity: +/-0.1% FS; Settling Time: <10 ms; Output Impedance: Voltage mode: <10 ohm; current mode: >10 Mohm; Load Capability: Voltage mode: >2 kohm; current mode: <600 ohm; Output Retention: Optional; restores the last output value after reboot when enabled
Communication
Interfaces: Opto-isolated RS485, optional RS232; Protocol: Modbus RTU / Modbus ASCII / Modbus TCP via gateway; Baud Rate: 600~115200 bps (auto-detect); Address Range: 1~255; Isolation Voltage: 1500 V RMS (RS485)
Mechanical
Dimensions: 100 x 70 x 35 mm

Y301-0008

Power Supply
Voltage: DC 12~30V; Typical Power Consumption: 11 mA @ 24V (~0.26 W); Operating Temperature: -40°C ~ +85°C; Humidity: 0% ~ 95% RH, non-condensing
Analog Outputs
Channels: 8; Output Type: 0-10 V, 4-20 mA, or combo option; combo versions support per-channel mode selection; Resolution: 14-bit (16384 steps); Accuracy: +/-0.1% FS; Linearity: +/-0.1% FS; Settling Time: <10 ms; Output Impedance: Voltage mode: <10 ohm; current mode: >10 Mohm; Load Capability: Voltage mode: >2 kohm; current mode: <600 ohm; Output Retention: Optional; restores the last output value after reboot when enabled
Communication
Interfaces: Opto-isolated RS485, optional RS232; Protocol: Modbus RTU / Modbus ASCII / Modbus TCP via gateway; Baud Rate: 600~115200 bps (auto-detect); Address Range: 1~255; Isolation Voltage: 1500 V RMS (RS485)
Mechanical
Dimensions: 100 x 70 x 35 mm